Electromagnetic valve installation and maintenance

by:Mech     2020-07-22

solenoid valve is one of the valve is commonly used in automatic control system, it with low cost, simple to use, convenient and reliable, Can directly to the PLC or DCS switch control signal) And get the consistent favour of users. It is a good thing, of course, also have to use when can play its proper function, the following is the electromagnetic valve in the installation and use simple descriptions need to be aware of maintenance problems.

installation note:

1, the first to check whether the electromagnetic valve is consistent with the selection of parameters, such as power supply voltage, medium pressure, pressure, power supply, in particular, if you make a mistake, will burn out the coil. Power supply voltage should be meet the rated voltage range: + 10% ~ - Dc + 10% ~ 15%, - 10%, coil components should not be open at ordinary times.

2, before taking over the pipe to wash, the metal powder in the pipeline and the sealing material residues, scale and rust removal, etc. To pay attention to the cleanliness of medium, if within the medium mixed with dirt and impurities, such as not impair the normal work of the solenoid valve, pipe should be installed in the filter or filter.

3, generally, electromagnetic valve, electromagnetic coil components should be vertical upward vertical installed in a horizontal pipe at the ground, if the space restrictions or conditions requirements must be installed according to the side, should be made in the selection when ordering. Otherwise may cause electromagnetic valve can't work normally.

4, electromagnetic valve should be added before and after the manual shut-off valve, at the same time should be bypassed, is advantageous for the solenoid valve in fault maintenance.

5, the electromagnetic valve is generally directed, not backward, usually the body using & rarr; Points out that the medium flow direction, to in accordance with the installation & rarr; Indicate the direction of the installation. But in the vacuum tube road or special circumstances can reverse.

6, if the water hammer will be the media, then you should choose waterproof hammer function of electromagnetic valve or take corresponding preventive measures.

7, try not to let the solenoid valve at a long time, this easy to reduce the service life of the coil and even burn out the coil, that is to say, normally open, normally closed electromagnetic valves cannot be used interchangeably.

8 with solenoid Industrial Valves, steam inlet side should be equipped with steam trap, it take over should tilt.

common faults of electromagnetic valve and eliminate

1, the electromagnetic valve does not work after the power supply: check whether the power connection bad & rarr; Connectors and wiring connection again; Check whether the power supply voltage is within the scope of work → Transferred to the normal position; Check whether the coil is desoldering & rarr; To welding. Coil short-circuit & rarr; Replace the coil; Working pressure difference is not appropriate & rarr; Adjust the pressure difference & rarr; Match or replace solenoid valve; The fluid temperature is too high & rarr; Change of proportion of electromagnetic valve; Have impurities to make electromagnetic valve of the main valve core and the moving core card die & rarr; For cleaning, such as sealing damaged seal and install the filter should be changed; Liquid viscosity is too large, the frequency is too high and the life has come & rarr; Replace the product.

2, electromagnetic valve can not close, the main valve core or moving iron core of seal damaged & rarr; Replace the seal; Whether the fluid temperature, viscosity too high & rarr; Replacement of the solenoid valve; Impurities into the electromagnetic valve is the main valve core or moving iron core & rarr; For cleaning; Spring had come to life or deformation & rarr; Replacement; Orifice balance hole plug & rarr; Timely cleaning; Working frequency is too high or life has come & rarr; For products or product update.

3, other conditions: internal leakage & rarr; Check whether the seal is damaged, the spring is bad assembly; External leakage & rarr; Joint looseness or seal has bad & rarr; Screw or replace the seal; Electricity from time to tome noise & rarr; The strong leader a loose and tighten. Voltage fluctuation is not allowed within the scope of adjust voltage. Core surface impurities or uneven absorption, clean or replace in a timely manner.


Shenzhen Mech Valve Trading Co., Ltd. have long believed that management practices are an important element in productivity.
You can find a large selection of quality at Mech Valve. Go get your desired one.
is something that has been around for a few decades now, enjoying it's heyday back in the resilient gate valve.
Shenzhen Mech Valve Trading Co., Ltd.'s flanged gate valve are sturdy, easy to operate, friendly work machines that deliver high-quality resilient seated valve for os gate valve purposes.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: