Professional Industrial Valves Manufacturer

Mech  >  AI - Page Sitemap  >  Mech antic reduced water pressure factory water pipe
Mech antic reduced water pressure factory water pipe

Mech antic reduced water pressure factory water pipe

Connection Ends
Flange to BS EN 1092-2:1997
Temperature Range
0℃- 80℃
Coating
Fusion Bonded Epoxy Coating in accordance with ANSI/AWWA C550
Working Pressure
PN10/PN16
Price
Get Latest Price
Get the latest price
Quantity Needed:
Pieces
E-mail:
Company Advantages
1. Mech reduced water pressure adopts a strict assembly process. This process includes adding solder paste to the PCB board, picking and placing components, and soldering. Quality materials such as stainless steel, copper alloy, and rubber are used for achieving its premium property
2. Investing in this product may seem like a costly investment at the moment, but in the long run, it is worth it. It can be used to increase production and save valuable time. It can be configured to operate electronically, manually or pneumatically
3. It is developed with the best functionality and quality. It is very tough and has excellent fatigue strength
4. The quality inspection standard of the product conforms to international norm. Its design helps to prevent backflow to some extent
Statement


SK790X Deluge Alarm Valve is a diaphragm type of hydraulic control valve driven by the hydraulic pressure within the piping system, functioning as flow control and alarming device in the sprinkler and pre-action system, i.e. to start the sprinkler system for quenching of the fire and send out fire alarm through the fire bell when there is fire detected.

Features


Operational principle

Mech antic reduced water pressure factory water pipe-1

SK790X Deluge Alarm Valve is equipped with solenoid, anti-reset controller, mini strainer, ball valve and pressure gauge, etc..

For deluge valve there is set condition and work condition. When the valve is under set condition, ball valve (3) is open, ball valve (7), solenoid (8) and remote ball valve (9) are closed, the anti-reset controller is connected, and pressure gauge (1) and pressure gauge (6) shows the same value. When ball valve (11) is open, pressure gauge (10) shows 0. When ball valve (12) and (14) are open, (13) & (15) closed, there is no hydraulic pressure for pressure switch (17) , and alarm (18) does not work. Under set condition, you can operate as following if you want to test the pressure switch alarm device (17) and water motor alarm (18): close ball valve (14) and open (15), and then close (15) and open (14) after testing.

In case there is fire detected, the following 3 methods will set the deluge valve into work condition immediately, A: Opening solenoid valve (8) B: Opening ball valve (7) C: Opening remote ball valve (9). Any of the above 3 methods can get the pressure within the control room of the basic valve released rapidly to open the valve and set it into working condition. At this time the sealing ball of anti-reset controller makes controller in a shutdown state, water will pass through the main valve, ball valve (12), (4), pressure switch (17), fire bell (18), the pressure switch bell sends out signal alarms. After fire fighting, close ball valve (7), solenoid valve (8), remote valve (9), press the anti-reset controller handle till the pressure gauge (6) and pressure gauge (1) shows the same value. The deluge alarm valves returns to set condition.Ball valve (2), (5) & (11) are normally open unless need to change the pressure gauge.


Property and advantages

• Driven by pressure of pipe system, work automatically with energy of pipe system to achieve energy conservation and environment protection.

• Controlled by the pilot valve, lower energy consumption, achieve accurate pressure reducing results, have function of stabilizing pressure after the valve.

• Dual cavity design, with functions of fully opening and fully closing. Slow shut causes no pressure fluctuation, and the diaphragm with support is well protected.

• Have internal orifice, connect bottom cavity and outlet of the basic valve, make sure stability of reaction to keep stability of pressure after the valve, avoid any vibration and noise.

• Channel with straight-flow, slight friction loss, no eddy flow and turbulent flow, cut down the damage of cavitation.

• Long pitch orientation design for stem move, stable and no gap resistance.

• Balanced automatically, big gap design on connection of disc and stem, disc is free on the vertical flat against stem, it can balance the tolerance from machining and sealing surface. Good connection without leakage. Achieve functions of both reducing dynamic pressure and reducing static pressure.

• Ductile iron castings with nodularity higher than 90%, foundry in house with advanced melting technology and strict quality control system, testing reports and testing bars can be supplied with order. Records and testing bars maintained for one year in the factory.

• Good corrosion resistance, with stainless steel, copper alloy, rubber made from DuPont and other rust- resisting material, fusion bonded epoxy coating both for interior and exterior surface of the basic valve. All the characteristics in accordance with ANSI/AWWA C550 and other international specifications like WRAS, NSF61.


Mech antic reduced water pressure factory water pipe-2
SK790X


Notes for installation and debugging

• Please check if pressure switch and alarm bell are in good condition before installation. Make sure water can not leak to system from water supplying system or there's equipment to discharge the leaked water.
Please adjust all the ball valves to make sure the basic valve be in set condition.

• Make sure anti-reset controller is in good condition and seal well before installation. If there's water with pressure in front of the valve, please closed ball valve (7), (9) and electromagnetic valve when it's in empty state behind the basic valve, press the anti-reset controller, when up cavity of basic valve is full of water please check if there's any leakage behind the valve. If no leakage, it said anti-reset controller is in good condition.


Typical installation illustration

Mech antic reduced water pressure factory water pipe-3


Common problems and proposed solutions



Common Problems

Proposed Solutions

 

Press anti-reset controller after fire-out, there's still water coming out behind the valve.

 

a.Check if any sundries or damage on the sealing surface of basic valve or anti-reset controller.

b.Check if any damage on diaphragm.
c.Check if controlling valve (7), (8) and (9) were closed completely. Close them or replace with new ones.

 

When open controlling valve (7), (8) and (9) no water comes out from the basic valve.

 

a.Check if controlling valve (7), (8) and (9) were opened. Close them or replace with new ones.

b.Check if there's block on stem of basic valve, repair it.


Company Features
1. The cultivation of professional talents and high-level technology helps the production of popular reduced water pressure .
2. We will adhere to the strict green production approach. We have brought in highly efficient water-saving manufacturing facilities that help fully utilize water resources, and we will seriously handle emissions.
Shenzhen Mech Valve Trading Co., Ltd. Introducing and learning foreign advanced technology and experience, combined with the company's own situation, developed a set of quality management system of its own, not only that, we also have multiple assembly lines for simultaneous production to ensure high quality At the same time, the output is also high.
Shenzhen Mech Valve Trading Co., Ltd.'s uses high-quality raw materials, durable products, long service life, scientific product structure design, excellent overall performance, and excellent workmanship, from details to the whole.
The company has many years of production and manufacturing experience, not only has professional production and quality inspection equipment, but also masters advanced manufacturing technology and technology, has established a rigorous and scientific quality management system, and produces with reliable performance and excellent quality , far exceeding peer products.
Shenzhen Mech Valve Trading Co., Ltd. Continuously absorb advanced management experience at home and abroad, introduce professional manufacturing and quality inspection equipment, actively learn industry-leading production technology and manufacturing process, and strive to improve the inherent quality of products to ensure that produced are of high quality Qualified product.
Shenzhen Mech Valve Trading Co., Ltd. has a modern production workshop and advanced production equipment, and has established a strict quality management system, and quality inspection personnel will conduct inspections in every link of production to ensure good quality and high quality excellent.
Strict testing: its current performance has been tested by third parties. It is also ready to be tested by users and will be continuously updated.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: