Solenoid valve failure and screening method

by:Mech     2020-08-12
Solenoid valve failure will directly affect the switching valve and control valve, common fault electromagnetic valve is not action, from the following several aspects: ( 1) Solenoid valve terminal is loose or falls off thrum, electromagnetic valve shall not electricity, can tighten thread ends. ( 2) Solenoid coil burn out, can remove the solenoid valve connection, measured with a multimeter, if open circuit, the electromagnetic valve coil burn out. Coil be affected with damp be affected with damp, reasons caused bad insulation and magnetic flux leakage, causing excessive current in coil and burned down, so to prevent rain water from entering the solenoid valve. In addition, the spring quality, reaction force is too large, the coil number of turns is too little, not enough suction also coil may be destroyed. When emergency treatment, but the manual button on the coil by the normal work of '0' to '1' bits, makes the Industrial Valves to open. ( 3) Electromagnetic valve stuck. The solenoid valve and the valve core set of fit clearance is small ( Less than zero. 008毫米) , are generally single assembly, when mechanical impurities into or lubricating oil is too little, it is easy to get stuck. Treatment methods available wire holes stab, from the head to make it back. The fundamental solution is to solenoid valve will be removed, remove the Industrial Valves core and valve core, clean with CCI4, makes the valve core within the valve sleeve flexible motion. Removal should be paid attention to when all parts, assembly sequence and wiring position to reassemble and wiring is correct, also check oil mist detector injection hole blockage, lubricating oil is enough. ( 4) Air leakage. Leakage will cause the air pressure is insufficient, make it easier for mandatory valve opening and closing, the reason is that sealing gasket damage or slide valve wear several cavity caused by gas. In dealing with the solenoid valve switch system failure, should choose the appropriate time, such as the solenoid valve in a loss of power, the if processing is not down in a switch gap, switched systems can be suspended, calmly deal with.
Shenzhen Mech Valve Trading Co., Ltd. continued to crave a more intense, personalized workout experience.
Shenzhen Mech Valve Trading Co., Ltd.’s goal is to achieve customer satisfaction through excellence in design, supply chain management, manufacturing and repair solutions.
gate valve also offers several other resilient seal gate valve that could potentially be useful for manufacturers.
Shenzhen Mech Valve Trading Co., Ltd. has enlarged the scope of services, which can fully please customers' demands.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: