Electromagnetic valve failure will directly affect the switching valve and control valve, common fault electromagnetic Industrial Valves is not action, screening from the following several aspects:

1) Solenoid valve terminal is loose or falls off thrum, electromagnetic valve shall not electricity, can tighten thread ends.

( 2) Air leakage. Leakage will cause the air pressure is insufficient, make it easier for mandatory valve opening and closing, the reason is that sealing gasket damage or slide valve wear several cavity caused by gas.

in the treatment of the switch system of the electromagnetic Industrial Valves failure, should choose the appropriate time, such as the solenoid valve in a loss of power, the if processing is not down in a switch gap, switched systems can be suspended, calmly deal with.

what methods of electromagnetic valve troubleshooting

3) Solenoid coil burn out, can remove the solenoid Industrial Valves connection, measured with a multimeter, if open circuit, the electromagnetic valve coil burn out.

coil be affected with damp be affected with damp, reasons caused bad insulation and magnetic flux leakage, causing excessive current in coil and burned down, so to prevent rain water from entering the solenoid valve. In addition, the spring quality, reaction force is too large, the coil number of turns is too little, not enough suction also coil may be destroyed. When emergency treatment, but the manual button on the coil by the normal work of '0 & quot; To '1 & quot; And makes the valve to open.

( 4) Electromagnetic valve stuck. The solenoid valve and the valve core set of fit clearance is small ( Less than zero. 008毫米) , are generally single assembly, when mechanical impurities into or lubricating oil is too little, it is easy to get stuck. Treatment methods available wire holes stab, from the head to make it back. The fundamental solution is to solenoid valve will be removed, remove the valve core and valve core, clean with CCI4, makes the valve core within the valve sleeve flexible motion. Removal should be paid attention to when all parts, assembly sequence and wiring position to reassemble and wiring is correct, also check oil mist detector injection hole blockage, lubricating oil is enough.


water gate valve has become a standardized way of dealing with os gate valve.
For more information please see our site at Mech Valve. Don't be hesitate to contact us!
Many business owners and professionals use services like Shenzhen Mech Valve Trading Co., Ltd. to stay on top of manufacturing industry, monitor products’ quality and keep an eye on competitors.
Knowing what promotions are popular and get the most activity as flow control valve from current and potential customers can play a role in your overall strategy.
Shenzhen Mech Valve Trading Co., Ltd., a manufacturer of resilient wedge gate valve, might emphasize less hassle or less wasted time rather than emphasizing reliability or quality.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: