Professional Industrial Valves Manufacturer

High-temperature solenoid valve installation method and use protection

by:Mech     2021-01-24
6, use for a long time, such as between piston and the valve seat tightly closed very bad, the piston can be tightly closed surface was smooth, grinding and seat again. 7, may not be used in explosive dangerous places. 9, before installation, pay attention to see the product sign, seriously read text, use conditions to determine whether a product meets. 2, the electromagnetic valve is installed to move count time into the medium experiment, clearly acknowledged, and normal rear can put into use. 8, on line rigidity is not enough conditions, proposed before the valve pipe bracket, lest solenoid valve actuating oscillation when the office. 5, installation, electromagnetic valve, Marine valve before the pipes must be clean and tidy. High-temperature solenoid valve used to protect and nurse 1, the proposed use unit to hold people accountable for protecting aftercare. 3, the electromagnetic valve failure occurs, in order to early isolation solenoid Industrial Valves, and guarantee the system normal operation, the best install bypass unit 4, in the pipeline system, installed on the branch of the solenoid valve size should be less than the main valve. Proposals before the valve installation filter device, the steam pipe installation steam trap. High-temperature solenoid valve installation: 1, the electromagnetic valve coil when installation progress, and maintain a straight position, the arrow or mark in the electromagnetic valve and piping to exactly the same, cannot install where there are splashing water or water leakage. 2, the electromagnetic valve of office medium should be cleaning without pellet impurity, electromagnetic trims the dirt from the appearance and filter, regular cleaning and tidy. 10, the electromagnetic valve should be installed in the pipeline before and after the pressure gauge, in order to take a closer look at pipeline pressure. When office pressure exceeds quota or office differential pressure exceeds quota differential pressure, electromagnetic valve applied to rest, closed before and after the manual valve, solenoid valve explosion and leak. 。 5, electromagnetic valve need not when, from the inside and parts should be wiping clean with compressed air blowing off storage. Q: high-temperature solenoid valve installation way, and used to protect a: high-temperature solenoid valve unique place: high temperature resistant, sees fit and use metal tightly closed, increased with temperature. Six, can not install the valve in the pipeline of dips, lest because of steam condensation water, impurities such as precipitation within the valve and prevent any action. 7, office, attention should be paid to the valve before and after the pressure gauge, pressure to office cannot exceed quota pressure, differential pressure of the office must be within the scope of the fixed pressure difference. 3, should be regular cleaning valve inside and bit off the dirt, be careful not to destroy tightly closed surface. 4, electromagnetic valve, a long time without manual valve before the valve should be closed, to start over, when using electromagnetic valve of steam condensate out should be neat, and try to move count time, and can be put into use after switch to normal. Wear-resisting, reasonable material selection, valve and guide sleeve house to use fluid of utility of lubricating oil, abrasion loss. Notes to the order: The national standard) A, A: B: product name, model, nominal size medium and temperature, pressure range C: whether there is attachment, delivery time, and special requirements so that we can correct selection for you. Second, if the valve has been selected by design unit of our company model, please order according to the valves parameters directly with our sales center. Three, it is very important when you use the occasion or the environment is more complex, would you please provide design drawings and detailed parameters, our engineers experts will concentrate on review and analysis for you. We can provide you with professional solutions, including design, customization, complete, operation and service. We've been working on the valve leader in the field of industry, to provide you with the latest knowledge of the valve, the best service, best technical adviser. Thank you for visiting our website, if you have any questions, you can call us, we will be dedicated to provide you with quality services. The factory provides professional ball valve, butterfly valve, gate valve, globe valve, check valve, relief valve, safety valve, Marine valve, oil valve, hydraulic control valve and other kinds of valves.
Shenzhen Mech Valve Trading Co., Ltd. is specialized in sourcing os gate valve resilient seated gate valve through its unparalleled worldwide network of supply. Go to Mech Valve, you will surely find your ideal at the most favorable price.
Shenzhen Mech Valve Trading Co., Ltd. will make a healthy profit for its owners and provide a rewarding work environment for its employees.
Shenzhen Mech Valve Trading Co., Ltd. quickly recognized the power of efficient manufacturing and started proactively recruiting people to sell products.
Shenzhen Mech Valve Trading Co., Ltd. undertakes all maintenance duties for ductile iron gate valve facilities and organizations and conducts all the security and surveillance for the properties.
Chat Online