My company manufacture ZJY46H piston type pressure reducing valve and diaphragm type pressure reducing valve is the difference of technical performance is the following:

serial number

ZJY46H piston type pressure reducing valve

differential pressure diaphragm type pressure reducing valve

project structure

characters

note

item

structure characteristics of the

note

1

the main valve structure

main regulating rod, main spring, cylinder liner piston assembly, streamlined throttling cone, outlet pressure lock lever

4 cavity structure make the control more sensitive and reliable; On the adjusting range is larger; Stress ratio can reach 10:1; Overall port their streamlined, medium flow regime is good, the noise is small; Simple and convenient maintenance; Volume and complex structure.

the main valve structure

diaphragm, diaphragm, disc, valve stem, plate type sealing disc

double cavity structure and double cavity water differential pressure control, pressure relief than 3:1; Plate type sealing disc medium flow difference, noise; Small volume, simple structure.

two

feedback control system

double feedback control system ( As spare) ; Piston valve ( Recoil sewage) ; Jet pump

as spare double feedback control system, can switch under the non-stop working condition; Piston valve to ensure safety operation; More sensitive can recoil emission control valve; Jet technology makes the main valve setting pressure more stable

feedback control system

upper and lower differential pressure diaphragm valve

3

outlet pressure ( P2) Stable stability

purple ping port power station P2 = 0. 4 mpa

outlet pressure ( P2) Relative poor stability

purple ping port power station P2 = 0. 4 mpa

4

running noises

60 decibels

ditto

running noises

70 decibels

ditto

5

the relief than

1

the relief than

three

6

P2 adjustable

0. 2 to 0. 8 mpa

P2 adjustable

0. 2 to 0. 5 mpa

7

flow

the same

flow

the same

and

adjustment way

feedback control system of jet technology combining pressure control and feedback control Industrial Valves; The main valve passive pressure cavity is not affected by the influence of inlet pressure P1.

when the large variation in P1; The P2 pressure stability is good;

when P2 flow change significantly; The P2 pressure stability is good;

upper and lower differential pressure diaphragm valve differential pressure control; P1 changes directly affect the regulation of

when the large variation in P1; The P2 pressure stability;

when P2 flow change significantly; P2 pressure stability

this is related to the principle diagram of the pressure reducing valve:

ZJY46H piston type pressure reducing valve

differential pressure diaphragm type pressure reducing valve


To be the best worldwide provider of higher-value flow control valve and the center for quality employment opportunities.
Super quality are in offer at Mech Valve, welcome to visit us.
With the market analysts, exports from Shenzhen Mech Valve Trading Co., Ltd. facilities in China will surpass the forecast.
[拓展名称] include a great variety of devices with a wide range of complexity: from simple resilient gate valve used since prehistoric times to the complex of modern mechanized os&y gate valve.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: