we integrated some customers for regulating valve products in use process, a series of questions caused our engineers to make the following solutions, suggest another customer please consulting engineers before selection, or the personnel of the service. Because selection is more important than calculation, calculation and selection of comparison, selection is much more important and more complex. Because computing is just a simple formula, its itself is not the accuracy of the formula, but in a given by process parameters are accurate. Selection involves the content is more, a little careless, will lead to improper selection, not only a waste of manpower, financial and material resources, and use effect is not ideal, so bring some use problems, such as feasibility, reliability and quality of life, running, etc.

a, regulator which several main functions are there? 1, regulating flow, pressure, adjust temperature, cut off the medium, the shunt confluence, etc.

2, why the regulator can produce oscillation in use process? 1, the regulator of the spring stiffness is insufficient, the regulator output signal is not stable and rapid changes in easy cause regulator oscillation. 2, and the selected valve at the same frequency and system frequency or pipe and a violent vibration, the regulator with the vibration. 3, improper selection of regulating valve working in a small open there is a sharp change of flow resistance, flow velocity, pressure, when more than valve stiffness, poor stability, serious when produce oscillation. 4, due to the causes of oscillation are various, specific analysis to specific issue.

three, double seal valve why cannot be used as a cut-off valve? 1, two-seat valve core has the advantage of force balance structure, allow the pressure difference is big, but its disadvantage is that the two seal face not good contact at the same time, cause leakage. 2, if it is artificially, forcibly used to cut off the occasion, obviously the result is bad, even as it made many improvements ( Such as double sealing sleeve valve) It is not desirable.

four criteria for the installation, the regulator is what? 1, the first valve installation shall be in accordance with the regulations of the design drawings and design documents strictly implement and performance of all inspection before installation. 2, consider the valve of the work environment adaptability, and the installation of the regulating valve, must ensure the safety, ensure the use of performance, easy operation and maintenance.

5, the regulator card plugging problems often? 1, the regulator, blocking often appear at the beginning of the new operation system and overhaul of commissioning, due to the pipe welding slag, rust and other body parts in the throttle opening and guide jam making medium circulation. 2, regulating valve overhaul sealed tight, causing friction increases, lead to small signal action, the phenomenon of large signal action too.

6, why quarter-turn valves to cut off the pressure difference is bigger? 1, quarter-turn valves to cut off the pressure difference is bigger, because the media on the valve core and valve plate produced by the resultant force on the rotating shaft torque is very small, so it can bear large pressure difference.

why two-seater, easy oscillation when small valve work? 1, for single core, when the medium is away, valve stability is good; When the medium is flow closed type, the stability of the valve. Two-seater valve has two valve core, the valve core flow closed, valve core in the flow, so that when you are working in a small open degree, flow closed type of valve core is easy to cause the vibration of the valve, this is the reason why two-seat valves cannot be used for small open degree work.

8, cut-off valve, why choose hard seal? 1, cut-off valve leakage, the lower the better, soft seal valve leakage is the lowest, to cut off the effect of course good, but not wear-resisting, poor reliability. From small leakage and sealing and reliable double standards, soft seal cutting is not as good as hard seal cut off. If the seal with a hard seal protection shut-off Industrial Valves, its reliable performance, leakage rate 10 ~ 7, have been able to meet the requirements of the cut-off valve.

9, general positioning device mainly exist the following fault type 1, by using mechanical force balance principle, the moving parts, more vulnerable to the influence of temperature, vibration, causing the regulator. 2, the nozzle baffle technology, as a result of nozzle hole is very small, vulnerable to dust or dirty air plug, make the positioning device can't work normally. 3, using force balance principle, the elastic coefficient of spring in bad change, caused by nonlinear led to the decrease of the quality of the control valve. Ten: welcome and look forward to your participation and technical difficulties, or if you have any more questions you are welcome to call consulting, valve and the exchange, because your participation we will become stronger, more professional.


With technology speeding up in lighting speed, have created quite a name for itself amidst resilient gate valve and it happens to have a lot of benefits as well.
Shenzhen Mech Valve Trading Co., Ltd. will accomplish this by exceeding the expectations of our customers while conserving resources and preserving the quality of the environment.
double flanged gate valve continued to evolve to having strong manufacturers develop huge marketers and people came to value their opinions about what to buy.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: