Professional Industrial Valves Manufacturer

Regulator of leakage fault handling methods

by:Mech     2020-08-12
Solenoid valve failure will directly affect the switching valve and regulating valve, below we from the following several aspects to analyze the electromagnetic valve of screening points: 1. In dealing with the solenoid valve switch system failure, should choose the appropriate time, such as the solenoid valve in a loss of power, the if processing is not down in a switch gap, switched systems can be suspended, calmly deal with. 2. Solenoid coil burn out, can remove the solenoid valve connection, measured with a multimeter, if open circuit, the electromagnetic valve coil burn out. Coil be affected with damp be affected with damp, reasons caused bad insulation and magnetic flux leakage, causing excessive current in coil and burned down, so to prevent rain water from entering the solenoid valve. In addition, the spring quality, reaction force is too large, the coil number of turns is too little, not enough suction also coil may be destroyed. When emergency treatment, but the manual button on the coil by the normal work of '0' to '1' bits, makes the valve to open. 3. Solenoid valve terminal is loose or falls off thrum, electromagnetic valve shall not electricity, can tighten thread ends. 4. Air leakage. Leakage will cause the air pressure is insufficient, make it easier for mandatory valve opening and closing, the reason is that sealing gasket damage or slide valve wear several cavity caused by gas. 5. Electromagnetic valve stuck. The solenoid valve and the Industrial Valves core set of fit clearance is small ( Less than zero. 008毫米) , are generally single assembly, when mechanical impurities into or lubricating oil is too little, it is easy to get stuck. Treatment methods available wire holes stab, from the head to make it back. The fundamental solution is to solenoid valve will be removed, remove the valve core and valve core, clean with CCI4, makes the valve core within the Industrial Valves sleeve flexible motion. Removal should be paid attention to when all parts, assembly sequence and wiring position to reassemble and wiring is correct, also check oil mist detector injection hole blockage, lubricating oil is enough.
looking for the best deal while getting a quality is usually the number-one objective for most os & y valve fire protection manufacturer.
Now you can enjoy os&y gate valve with Shenzhen Mech Valve Trading Co., Ltd.'s latest collection of cast iron valve resilient seated gate valve products. Do visit now, at Mech Valve.
The only cardinal rule with adding animation is to keep high-quality on ductile iron gate valve.
There are ample scientific evidence of reducing the risk of resilient seal gate valve.
If something seems too good to be true, then it can be a , which provides resilient seated valve value over its cost.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: