The reversing valve fault and maintenance

by:Mech     2020-08-13
Reversing valve failure are: valve cannot reversing or reversing slow, gas leak, such as electromagnetic pilot Industrial Valves has some problem. ( 1) Reversing valve cannot reversing or reversing slow, usually because of bad lubrication, spring stuck or damage, oil or impurity sticking sliding part and other causes. To this, should first check of oil mist is normal; The viscosity of the lubricating oil. When necessary, should replace lubricating oil, cleaning sliding part of the directional control valve, or replace spring and directional control valve. ( 2) Directional control valve is seen after long time use the sealing ring wear, the valve stem and valve core seat damage phenomenon, lead to gas leakage in the valve, valve slow or can't normal commutation failure, etc. At this point, a seal, valve stem and seat should be replaced, or will the reversing valve. ( 3) If electromagnetic pilot valve inlet and vent was sludge and other debris jam, closed lax, activity core was jammed, a fault circuit, etc. , all can lead to directional valve can't normal commutation. The former three kinds of activities should be cleaning pilot valve and core on the sludge and impurities. And circuit fault generally divided into two groups: the control circuit fault and electromagnetic coil. Before checking circuit fault, should be the reversing valve manual knob turn a few times, see if the reversing valve under the rated pressure can normal commutation, if can normal commutation, circuit is defective. Check, instrument measuring electromagnetic coil voltage are available, and see if the rated voltage, if the voltage is too low, should further check the control circuit of the power supply circuit and associated travel switch. If under the rated voltage directional valve can't normal commutation, should check the joint of electromagnetic coil ( Plug) Whether loose or exposure to false. Method is to remove the plug, measuring coil resistance, if the value is too big or too small, and explain the electromagnetic coil is damaged, should be replaced.
In an age when flanged gate valve is increasingly important, the researchers believe manufacturers should pay close attention to their results.
To know more about wedge valve, please check our website at Mech Valve.
need fuel for energy,while resilient gate valve do not.
Now that Shenzhen Mech Valve Trading Co., Ltd. has become a leader in the space and have been able to scale appropriately, we are ready to expand to other cities.
Shenzhen Mech Valve Trading Co., Ltd. knew the only way to remain competitive was to ensure quality of service and customer satisfaction above all.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: