Applicability:

fluid pipeline must be solenoid valve series models in the calibration and use of medium.

the temperature of the fluid must be smaller than choose the calibration temperature of the solenoid valve.

general under 20 CST electromagnetic valve to allow the liquid viscosity, more than 20 CST should be marked.

work pressure difference, line the high-pressure difference in less than 0. 04 mpa should be chosen as ZS, 2 w, ZQDF, ZCM series and type of moving step by step straight acting; The minimum working pressure difference is greater than zero. 04 mpa when guiding type (optional Differential pressure type) Electromagnetic valve; Maximum working pressure difference should be less than the biggest calibration pressure solenoid valve; General solenoid valve is a one-way work, so should pay attention to whether there is a pressure difference, install the check valve.

fluid cleanliness is not high when the filters should be installed in front of the solenoid valve, general electromagnetic

the cleanliness requirements for medium is better.

note that flow aperture and aperture; Two solenoid valve usually only switch control; Conditions permit, please install bypass pipe, easy maintenance; When there is water hammer to customize solenoid valve opening and closing time to adjust.

pay attention to the environmental temperature on the influence of electromagnetic valve

power supply current and power consumption should be selected according to the output capacity, power supply voltage generally allow & plusmn; About 10%, must pay attention to communication when starting the VA value is higher.

2, reliability,

solenoid valve normally open and normally closed; General selection normally closed type, electric open, power is shut down; But when opened for a long time closed in very short time to choose the normally open type.

life test, the factory generally belongs to the type testing project, specifically haven't solenoid valve professional standards in our country, so choose carefully when the solenoid valve manufacturer.

action time is very short at high frequency generally choose straight acting, large-caliber choose fast series.

3, safety

general solenoid valve is not waterproof, when conditions are not allowed to use waterproof model, the factory can be customized.

the highest calibration nominal pressure solenoid valve must be more than the highest pressure in the pipeline, otherwise life will shorten or other unexpected circumstances.

corrosive liquid should be chosen in all stainless steel type, appropriate chooses the corrosive fluid plastic king ( SLF) Solenoid valve.

explosive environment must choose corresponding explosion-proof products. Four, economy

there are a lot of solenoid valve can be common, but are able to meet the above three points should be chosen on the basis of most economic products.

the structure and principles of electromagnetic valve

a: direct acting solenoid valve

there are normally closed type and open type two kinds. Normally closed type power outages are closed, when the coil electricity to produce electromagnetic force, the moving core to overcome the spring force with the static iron core and open the valve directly, medium is access; Disappear when the power coil electromagnetic force, under the action of spring force of moving iron core reset, close the Industrial Valves port directly, medium. Simple structure, reliable action, under the zero pressure difference and micro vacuum to work normally. Normally open type is just the opposite. If less than & phi; 6 flow path of electromagnetic valve. ( Figure 1 is a typical chart)

2, step by step direct acting solenoid valve

this valve adopts an open Industrial Valves and the second opening valve in an organic whole repeatedly, the main valve and pilot valve by electromagnetic force and pressure difference directly open the main valve. When energized coil, thus moving iron core and static iron core and electromagnetic force, pilot valve is located in the main valve and pilot valve mouth mouth open mouth, and the moving core and the main valve core together, at this time the main valve cavity pressure on the unloading, through the pilot valve port under the action of pressure difference and the electromagnetic force at the same time the main valve core upward movement, open the main valve medium circulation. Disappear when the power coil electromagnetic force, the moving core under the action of gravity and spring force, close the valve guide hole, the medium in the balance hole into the cavity on the main valve core, make the cavity pressure, at this time in the spring return and pressure under the action of closing the main valve, medium. Reasonable structure, reliable operation, work is reliable when zero pressure difference. Such as: ZQDF, ZS, 2 w, etc. ( Figure 2 is a typical chart)

3, indirect guiding type solenoid valve

the series solenoid valve by the pilot valve and main valve core is linked to the channeling combination; Normally closed type in an unpowered, is closed. When energized coil, the magnetic force made moving iron core and static iron core or absorption, pilot valve to open the mouth, medium of exports, reduce the cavity pressure at this time the main valve core and is lower than the inlet side of the pressure, formation pressure difference to overcome the spring resistance and then upward movement, achieve the purpose of opening the main valve mouth, medium circulation. Disappear when coil electricity, magnetism, moving iron core under the action of spring force reduction and shut down the forerunner, the medium flow from balance hole, the main valve cavity pressure on the core, and under the action of spring force downward movement, close the main valve. Often open principle is just the opposite. Such as: the SLA, DF ( φ More than 15 diameter) , ZCZ, etc. ( Figure 3 is a typical chart)


Shenzhen Mech Valve Trading Co., Ltd. will continue to build a corporate culture that respects and values the unique strengths and cultural differences of our associates, customers and community.
Mech Valve is the vital link in the supply chain, adding value with efficient and cost-effective service and solutions for our customers and our suppliers.
Shenzhen Mech Valve Trading Co., Ltd. is an online resource for today's modern woman to live a green, healthy, and happy life. We offer double flanged gate valve, os&y valve and more! Pls visit our site at Mech Valve to know more.
Shenzhen Mech Valve Trading Co., Ltd. deems that we can drive consumer transactions using high-tech tools like artificial intelligence and cognitive data sets.
Chat Online
Chat Online
Chat Online inputting...
Sign in with: